Danfoss AK-CC 550 Mode D'emploi page 16

Masquer les pouces Voir aussi pour AK-CC 550:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Menu survey
Parameter
Function
Normal operation
Temperature (setpoint)
Thermostat
Differential
Max. limitation of setpoint setting
Min. limitation of setpoint setting
Adjustment of temperature indication
Temperature unit (°C/°F)
Correction of the signal from S4
Correction of the signal from S3
Manual service, stop regulation, start regulation (-1, 0, 1)
Displacement of reference during night operation
Define thermostat function
1=ON/OFF, 2=Modulating
Definition and weighting, if applicable, of thermostat sen-
sors - S4% (100%=S4, 0%=S3)
Time between melt periods
Duration of melt periods
Temperature setting for thermostat band 2
use r01
S6
Correction of the signal from
Definition and weighting, if applicable, of thermostat sen-
when night cover is on. (100%=S4, 0%=S3)
sors
Heat function
Neutral zone between refrigeration and heat function
Time delay at switch between refrigeration and heat
function
Alarms
Delay for temperature alarm
Delay for door alarm
Delay for temperature alarm after defrost
High alarm limit for thermostat 1
Low alarm limit for thermostat 1
High alarm limit for thermostat 2
Low alarm limit for thermostat 2
High alarm limit for sensor S6 at thermostat 1
Low alarm limit for sensor S6 at thermostat 1
High alarm limit for sensor S6 at thermostat 2
Low alarm limit for sensor S6 at thermostat 2
S6 alarm time delay
With setting = 240 the S6 alarm will be omitted
Alarm time delay or signal on the DI1 input
Alarm time delay or signal on the DI2 input
Signal for alarm thermostat. S4% (100%=S4, 0%=S3)
Delay for S6 (product sensor alarm) after defrost
Compressor
Min. ON-time
Min. OFF-time
Time delay for cutin of comp.2
Defrost
: 0=none, 1= EL, 2= Gas
Defrost method
Defrost stop temperature
Interval between defrost starts
Max. defrost duration
Displacement of time on cutin of defrost at start-up
16
Code
1
2
- - -
1
1
r01
1
1
r02
1
1
r03
1
1
r04
1
1
r05
1
1
r09
1
1
r10
1
1
r12
1
1
r13
1
1
r14
1
1
r15
1
1
r16
1
1
r17
1
1
. As differential
r21
1
1
r59
1
1
r61
r62
r63
A03
1
1
A04
1
1
A12
1
1
A13
1
1
A14
1
1
A20
1
1
A21
1
1
A22
1
1
A23
1
1
A24
1
1
A25
1
1
A26
1
1
A27
1
1
A28
1
1
A36
1
1
A52
1
1
c01
1
1
c02
1
1
c05
d01
1
1
d02
1
1
d03
1
1
d04
1
1
d05
1
1
Instructions RI8LN452 © Danfoss 05/2008
EL-diagram page 2 or 3
Min.-value Max.-value
3
4
5
6
7
8
9
10
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
SW = 1.2x
Factory
setting
-50°C
50°C
2
0.1 K
20 K
2
-49°C
50°C
50
-50°C
49°C
-50
-10
10
0
0/°C
1/F
0°C
-10 K
10 K
0
-10 K
10 K
0
-1
1
0
-25 K
25 K
0
1
2
1
0 %
100 %
100
0 hrs
10 hrs
1
0 min.
10 min.
5
-50°C
50°C
2
-10 K
10 K
0
0 %
100 %
100
0 K
50 K
2
0 min.
240 min.
0
0 min.
240 min.
30
0 min.
240 min.
60
0 min.
240 min.
90
-50°C
50°C
5
-50°C
50°C
-30
-50°C
50°C
5
-50°C
50°C
-30
-50°C
50°C
5
-50°C
50°C
-30
-50°C
50°C
5
-50°C
50°C
-30
0 min.
240 min.
30
0 min.
240 min.
30
0 min.
240 min.
30
0 %
100 %
100
0 min.
240 min.
90
0 min.
30 min.
0
0 min.
30 min.
0
0 sec
999 sec
5
0/No
2/GAs
1/EL
0°C
25°C
6
0 hrs/Off
48 hrs
8
0 min.
360 min.
45
0 min.
240 min.
0
AK-CC 550
Actual
setting

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

084b8020084b8021

Table des Matières