8.0

RESPIRATOR INSPECTION

COMPONENT
HEAD STRAP
• Remove the old head strap from the facepiece, noting the routing of the straps.
AND HEADNET
• Install new head strap or headnet.
O-RING, GASKET,
• To remove, rotate the connector clockwise. Lift the connector hook and rotate the connector
CONNECTOR
• Remove the o-ring from the groove in lens.
• To install, place the o-ring into the groove on the lens with the part number tab aligned with the slot.
• Align the three lugs on the underside of the connector with the three slots in the lens. Insert the
• Install the new gasket groove side up onto the connector. The gasket must be seated below the
NOZZLE COVER
• To remove, pinch the two lower latches while lifting the lower tab.
• Disengage the upper hook by lifting the cover upward.
• To install, engage the cover on the nozzle upper hook.
• Rotate cover downward until both lower latches engage the cover. An audible click should be heard.
counterclockwise, and pull outward.
connector into the lens port and rotate clockwise. An audible click should be heard.
connector threading.