2.3
ATTACHING FILTER, FILTER ASSEMBLY OR CARTRIDGE, FILTER/CARTRIDGE ON FACEPIECE
1)
When attaching your filter, filter assembly, or cartridge, filter/cartridge onto the facepiece;
a)
Verify the connector gasket is properly attached to the connector,
b)
ensure the filters or cartridges do not cross thread. Turn cartridges until they are seated snugly against the gasket and
you notice resistance to further turning. Ensure the cartridges are flush with the facepiece seal, the cartridge connectors
and gaskets are also flush with the inside of the mask, and
c)
do not over tighten as this may crack the cartridge connectors (see Figure 5). Tug slightly on your filter / cartridge
assembly to assure that they are firmly affixed.
2.4
PRESCRIPTION EYEWEAR AND SPECTACLE INSERTS
If you use prescription eyewear, Honeywell offers a spectacle insert. Refer to OPTIONAL ACCESSORIES for a listing. Follow the
instructions with your spectacle insert to assemble to the facepiece.
Filters, cartridges, and filter cartridge combinations must be the same on both sides of the respirator. NIOSH and AS/NZS
certifications and all Honeywell warranties for this respirator are nullified if cartridges and/or filters other than those set forth
on the approval labels are used.
Only use filter, cartridges or filter cartridge combinations for protection from contaminants listed on that filter or cartridge
NIOSH or AS/NZS Approval Label.
Failure to comply with these warnings will result in the risk of serious injury, illness or death.
Cartridge Filter
Figure 5
WARNINGS
11
Lens/Facepiece