DIODE TEST
1. Insert RED test lead into VΩµA jack
into COM jack
Continuity/Resistance/Capacitance/Diode-Test
NOTE: The meter defaults to Continuity testing in this mode. Press
the "SELECT" button
The Diode icon
2. Touch test leads to diode. A reading of 200-800mV on display
indicates forward bias, "OL" indicates reverse bias. An open
device will show "OL" in both polarities. A shorted device will
show approximately 0mV.
Black lead
FREQUENCY / DUTY-CYCLE
1. Insert RED test lead into VΩµA jack
into COM jack
Frequency/Duty-Cycle
NOTE: The meter defaults to Frequency testing in this mode. To enter
Duty-Cycle testing mode, press the "SELECT" button
that the appropriate icon (either Hz or % ) appears on the display.
2. Measure by connecting test leads across the circuit.
Black lead
OPERATING INSTRUCTIONS
, and rotate function selector switch
4
three times to enter Diode testing mode.
12
will appear on the display.
Red lead
, and rotate function selector switch
4
setting.
Red lead
, and BLACK test lead
5
and BLACK test lead
5
12
to the
2
setting.
to the
2
once. Ensure
15