AC CURRENT (LESS THAN 600A)
AC Current is measured by pressing the clamp trigger
the clamp and placing it around a current-carrying wire. When
measuring, care should be taken to ensure that the clamp is
completely closed with trigger
passes perpendicularly through the center of the clamp in line with
the arrow markings
To measure current:
1. Rotate the Function Selector switch
to the A~ setting.
2. Place clamp around wire. The current
measurement will be shown in the display.
Disconnect test leads when
measuring with the clamp.
AC/DC VOLTAGE (LESS THAN 600V)
1. Insert RED test lead into VΩµA jack
into COM jack
V
setting for AC or DC measurements. The meter defaults to
AC measurement. To measure DC, press the "SELECT" button
to toggle between AC and DC modes. The AC or DC icon on
12
the LCD indicates which mode is selected. Note "AC" or "DC" on
the display.
Black lead
10
OPERATING INSTRUCTIONS
10
.
11
, and rotate function selector switch
4
Red lead
fully released, and that the wire
NOTE: Current
measurement can be
made by clamping
around single
conductors, but not
cables containing
both live and neutral
wires. In this case a
line splitter is required,
Klein Cat. No. 69409 is
recommended.
2
, and BLACK test lead
5
to open
10
to the