ENGLISH
DIODE TEST
1. Insert RED test lead into V jack
jack
, and rotate function selector switch
4
2. Touch test leads to diode. A reading of 200-700mV on display
indicates forward bias, OL indicates reverse bias. An open
device will show OL in both polarities. A shorted device will
show approximately 0mV.
Black lead
BATTERY TEST
1. Insert RED test lead into V jack
COM jack
or 9V battery test setting.
2. Connect BLACK lead to negative, and RED lead to positive
terminal of battery.
3. Measure voltage on display, batteries in good condition should
be within approx. 10% of rated voltage.
Black lead
DATA HOLD
Press Data Hold button
Press again to release the display and return to live measuring.
10
OPERATING INSTRUCTIONS
Red lead
, and rotate function selector switch
4
Red lead
to hold the measurement on the display.
6
and BLACK test lead into COM
5
to the
2
and BLACK test lead into
5
setting.
to the 1.5V
2