CONNECTIONS.
Mains voltage.
- Check the conformity of the power supply unit.
Rating plate 10 : Lamp power.
Lighting unit / Power supply connection.
- Connect the lamp cable
ballast and connector e
- Lock the cable C into the cable lock j .
- Connect the cable
D
ballast and to the connector
- Place the lamp into position - refer to page 16.
- Connect the DATA line on connector ( a ) "XLR5" or
the analog command to the the connector ( c ) "XLR4".
( For the connection configurations : refer to page 24 ).
- Connect the optional units that are possible, to connector h
( Only DATA ).
- Plug the cable
8
to the mains. If the power is present, the
checklight 1
lights up immediately.
- Engage the automatic breaker 3 and check that the CAD 900
protection 4
is well engaged.
- Engage the automatic breaker 2 .
WARNING !
- Never open the lantern's bonnet when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when lamp is in place.
14
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
2500W HMI FOLLOW SPOT
A
f
e
j
C to the connector
7 of the
to the lighting unit.
to the connector ( d ) of the
g of the lighting unit "XLR7".
TECHNICAL FILE
g
h
C
B
DESCRIPTION.
A 1039 B/1439 B - Motorized shutter with CAD.
e - EM HARTING 16 x 16A power socket.
f - 10A. 250V. EEC - Female mains socket.
g - EM XLR7 shutter + DATA.
h - EF XLR5 output DATA.
B Power supply unit.
1 - Mains checklight.
2 - UNI + N 2A-C automatic breaker.
3 - General 25A automatic breaker.
4 - UNI + N 2A-C automatic breaker.
6 - Ventilation opening
7 - EF HARTING 16 x 16A - 2 latch connector.
8 - Mains cable 3 x 4 mm
9 - CAD 900 local controls.
C A D 900
0/10V - DMX 512 - AVAB
ERROR
SELECT
DATA
EXT. DIGI.
LOCK
EXT.
LOCAL
RESET
a b c d
DATA
CONTROL
10 - Rating plate.
11 - Power supply selector :
208V. 60Hz, 230V. 50Hz & 245V. 50Hz.
Position locked by a screw.
C Lamp cable.
Cable H07 RN-F 19G1,5 mm
with 16 x 16A M/F HARTING connectors.
D Shutter cable.
14 conductors reinforced shielded cable - length 3m
fitted with XLR7 M/F connector.
E Analog control fader cable.
14 conductors reinforced shielded cable - length 3m
fitted with XLR4 M/F connector.
1039B & 1439B
VALID SINCE : 09.05.01
E
D
Power supply unit
(P.S.U.)
DATA Line.
(DON'T OBSTRUCT THE AIR GAPS).
2
(3m)+P17 32A. + T plug.
a - EM XLR5 : DATA input.
b - EF XLR5 : DATA output.
EXIT
+
c - EM XLR4 : 0/+10V. input.
d - EF XLR7 : lighting unit output.
0/10V
SHUTTER
2
length 3m fitted
DATA
DMX 512 Line.