CONNECTIONS.
Mains voltage.
- Check the conformity of the power supply unit.
Rating plate 11 : Lamp power.
Lighting unit / Power supply connection.
- Connect the lamp cable
ballast and connector d to the lighting unit.
- Lock the cable C into the cable lock f .
- Place the lamp into position - refer to page 16.
- Engage the automatic breaker 3 and check that the protection
4 is well engaged.
- Plug the cable
8
to the mains. If the power is present, the
checklight 1 lights up immediately.
- Engage the automatic breaker 2 .
WARNING !
- Never open the lantern's bonnet when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when lamp in place.
12
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
2500W HMI FOLLOW SPOT
A
e
d
f
C to the connector
7 of the
C
B
DESCRIPTION.
A 1039/1439 Manual shutter version.
d - EM HARTING 16 x 16A power socket.
e - 10A. 250V. EEC - Female mains socket.
B Power supply unit.
1 - Mains checklight.
2 - UNI + N 2A-C automatic breaker.
3 - General 25A automatic breaker.
4 - UNI + N 2A-C automatic breaker.
6 - Ventilation opening
7 - EF HARTING 16 x 16A - 2 latch connector.
8 - Mains cable 3 x 4 mm
9 - Lamp ON, checklight.
10 - "ON/OFF" switch.
When the switch is ON and the checklight is OFF,
the lighting of the HMI lamp has failed.
Repeat the operation.
11 - Rating plate.
12 -
External control
by a straight closing contact (1A - 250V).
13 - Power supply selector :
208V. 60Hz, 230V. 50Hz & 245V. 50Hz.
Position locked by a screw.
C Lamp cable.
Cable H07 RN-F 19G1,5 mm
with 16 x 16A M/F HARTING connectors.
1039 & 1439
VALID SINCE : 09.05.01
Power supply unit
(P.S.U.)
(DON'T OBSTRUCT THE AIR GAPS).
2
(3m)+P17 32A+E plug.
2
length 3m fitted