Robert Juliat HELOISE Dossier Technique page 46

Masquer les pouces Voir aussi pour HELOISE:
Table des Matières

Publicité

1.2. Untimely extinction of the lamp.
2. USING THE " ANALOG " MODE
2.1. The ballast and the CAD are on ;
the" lamp on" command is given,
but the lamp does not switch on.
2.2. Intimely extinction of the lamp.
46
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
2500W HMI FOLLOW SPOT
message displayed :
LAMP OFF
CHECK SECURITY
message unchanged.
message unchanged.
message displayed :
RJ LAMP LIGHTING
TRY FAILURE
message displayed :
LAMP FAILURE
CHECK SECURITY
message unchanged.
Message in
start-up display :
" RJ LAMP OFF "
Return to 1.1 and follow the
procedure.
Network transient failure : give the
off command, or switch off
the mains for 30 sec.
Check the analog command cable :
the command has not been
recieved.
( refer to Tech. File p. 14 & 24 )
Return to 1.1 and follow the
procedure.
Return to 1.1 and follow the
procedure.
Network transient failure : give the
off command, or switch off
the mains for 30 sec.
Command signal failure :
check the cable
( refer to Tech. File p. 14 & 24 )
1039B & 1439B
VALID SINCE : 09.05.01
Restart the
"LAMP ON"
procedure.
Restart the
"LAMP ON"
procedure.
Restart the
"LAMP ON"
procedure.
Restart the
"LAMP ON"
procedure.