NB!
It is forbidden to use a non-heat-resistant cable with PVC isolation
as the power cable. The joint box must be waterproof and it must be
located up to 50 cm from the floor.
Open the cover of the heater's electrical box.
Attach the power cable on the terminal block according to the
circuit diagram.
Close the cover.
Fix the cable on the output with a cable strap.
L1 L2
L3 N
400V 3N
Fitting the stones
The stones must be washed clean before laying.
Make sure that the heating elements are not bent during the
process.
There must be sufficient air circulation around the heater
elements.
Stack the stones sparsely between the heating elements. If the
stones have been stacked too close to each other, the heating
elements may overheat (= shorter useful life) and slow the
heating of the sauna.
Stones with a diameter of 5-10 cm are suitable for the heater.
The stones on the external surface of the heater must be
stacked close to one another. The heating elements must not be
visible.
Using ceramic stones in the HIVE heater is allowed at the user's
responsibility.