THINGS TO CHECK BEFORE INSTALLATION
Does the output (kW) match the volume (m
See Table 1.
In case there are any uninsulated brick, tile or glass walls in the
sauna room, an additional volume of 1.5 m³ should be added to
the sauna room for each such square meter of the wall.
The suitable output of the heater will be determined based on
that volume according to Table 1.
The producer's warranty guarantee is invalid if the heater and
sauna room have been dimensioned incorrectly!
Minimal safe distances between the sauna room's ceiling and
walls to consider in installing the electric heater are listed in
Table 1.
INSTALLATION
Positioning the heater
The heater must be positioned in such a way that there is a safe
distance between flammable materials and the external surfaces
of the heater. See Figure.
In installing the heater, it must be prevented that people could
have physical contact with the heater or that other dangerous
situations could emerge during the heating process.
The heater holds approximately 270 kg of stones.
The inputs of the power cable are on the bottom cover of the heater.
Table 1
HIVE Mini 6
HIVE Mini 9
HIVE Mini 10,5
HIVE 12
HIVE 15
HIVE 18
4
Output
Room
kW
m
3
6
5-8
9
9-15
10,5
10-20
12
12-25
15
15-30
18
18-35
Weight
A
kg
mm
14
60
16
90
16
110
20
120
21
150
22
180
) of the sauna room?
3
B
Ø
mm
mm
580
460
640
460
680
460
800
560
860
560
920
560
H
mm
750
750
750
750
750
750