Capacitance
100.0 nF, 1000 nF, 10.00 µF, 100.0 µF
1)
Accuracy below 50 nF is not specified
2)
Accuracies with film capacitor or better
3)
Top range. Updates > 1 minute on large values
4)
Specified with battery voltage above 2.8 V (half full battery). Accuracy decreases gradually to
12% at low battery warning voltage of approx. 2.4 V.
Resistance
6.000 kΩ
60.00 KΩ, 600.0 KΩ
6.000 MΩ
Open Circuit Voltage: 0.4 V dc typical
1)AutoTect is for 6.000 kΩ ~ 6.000 MΩ ranges;
2)Add 40 d to specified accuracy when reading is below 20% of range
1
Range
3)
1
Range
±(3.5%+6 dgt)
±(1.2%+6 dgt)
±(1.0%+4 dgt)
±(2.0%+4 dgt)
13
2
Accuracy
4
2
Accuracy