1.3.3 Activation of the radio interface
The radio interface leaves the factory deactivated. It can be activated as follows:
a) The radio function can be activated by pressing the push-button.
Press the push-button until you change to the display loop "6" (module loop). Then change with a brief keystroke to the 2nd
item "rad(io) off" (see picture).
In order to start the editing mode you afterwards must press the push-button
once again for 2-3 seconds. As an aid, after 2 seconds the "editing pen" will be displayed
bottom left in the LCD. As soon as it appears you have to let go of
the button. Now the display shows "rad(io) on" and in all display loops a black triangle
picture).
b) The radio function can also be activated using a suitable configuration software.
This software can be ordered separately as an option.
The radio function can only be deactivated using the suitable configuration software.
After activation of the radio function or modification of the radio parameters the meter remains in installation mode for 60
minutes. During this time he sends telegrams in a 36-seconds-interval.
If using the compact mode, after activation the meter transmits during installation mode format telegrams and compact
telegrams alternately.
During installation mode at least one meter of the version being installed (inlet or outlet flow, heat or heat/cooling, pulse
inputs, display units) must be read out with a read-out software. The format of the telegram will be stored locally in the PC in
an .xml file.
After completion of the installation mode only compact telegrams will be transmitted.
1.3.4 Later activation of the radio encryption
The AES encryption can also be activated later. It can be activated as follows: a)
The encryption can be activated by pressing the push-button.
Press the push-button until you change to the display loop "6" (module loop). Then change with a brief keystroke to the 3rd
item "AES off" (see picture).
In order to start the editing mode you afterwards must press the push-button once
again for 2-3 seconds. As an aid, after 2 seconds the "editing pen" will be displayed
bottom left in the LCD. As soon as it appears you have to let go of the button. Now the
display shows "AES on" (see picture).
b) The encryption can also be activated using a suitable configuration software. This
software can be ordered separately as an option.
The encryption can only be deactivated using the configuration software.
1.4 Three additional pulse inputs (optional; only in conjunction with M-Bus or radio)
With this option, additional instruments with pulse outputs can be read out via optical interface, M-Bus or radio.
General information about pulse inputs:
It is important to note that the acknowledged state of the art technology rules and the relevant legal restraints (international
and local; see "Relevant Norms / Standards / Literature Pulse Inputs") are to be observed.
The installation has to be performed by authorized, skilled persons.
If the regulations and the information in the installation and operating instruction manuals are not strictly followed, or if the
installation is shown to be faulty, any resulting expenses will be charged to the company responsible for the installation.
1.4.1 Relevant norms / standards / literature pulse inputs
IEC 60364-4-41 (2005-12)
IEC 60364-4-44 (2007-08)
IEC 60364-5-51 (2005-04)
IEC 60364-5-54 (2011-03)
Page 99 of 108
Article no.: 1080619046
Low-voltage electrical installations - Part 4-41: Protection for safety - Protection against
electric shock
Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against
voltage disturbances and electromagnetic disturbances
Electrical installations of buildings - Part 5-51: Selection and erection of electrical
equipment - Common rules
Low-voltage electrical installations - Part 5-54: Selection and erection of electrical
equipment - Earthing arrangements and protective conductors