200Ω range: Measured value = (Measured display value)
– (Short-circuiting value of probe)
Open circuit voltage: around 0.5V
Overload protection: 600V
4.
: Continuity
Range Resolution
G
Overload protection: 600V
5. Battery Test
Range
1.5V
9V
Overload protection:
F1 fuse, 0.5A H 660V fast-fuse, 6.3x32mm
For 1.5V range: Load resistance is around 30Ω.
For 9V range: Load resistance is around 1kΩ.
G : Diode measurement
Open circuit voltage is around 0.5V.
Resistance >150Ω, buzzer will not
sound.
0.1Ω
Resistance ≤10Ω, buzzer will sound.
11 < Resistance < 150.........Not
Specified.
Open-circuit voltage is around 1.5V.
1mV
Normal voltage is around 0.5V to
0.8V for silicon PN junction.
Resolution
10mV
Accuracy
±(10%+3dgt)