VOLTCRAFT VC250 Notice D'emploi page 50

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Resistance
Range
Accuracy
VC250
200 Ω
2 kΩ
20 kΩ
±(1.0% + 8)
200 kΩ
2 MΩ
20 MΩ
±(1.6% + 7)
Overload protection 600V, measurement voltage: approx. 0.45 V
Capacity
Range
VC270/290
40 nF
400 nF
4 µF
40 A
100 µF
Overload protection 600V
Frequency
Range
VC270/290
10 Hz – 10 MHz
Overload protection 600V
Sensitivity ≤1 MHz : 300 mV; Amplitude max. 30 V
Sensitivity >1 MHz : 600 mV; Amplitude max. 30 V
Battery Test
Range VC250
1.5 V
9 V
Overload protection: self-resetting PTC fuse
50
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
VC270
±(3,9% + 13)
±(3,9% + 7)
±(5,2% + 7)
VC290
Load resistance
approx. 15Ω
approx. 1kW
Range
VC270/290
VC270
400 Ω
±(1.5% + 10)
4 kΩ
40 kΩ
±(1.3% + 2)
400 kΩ
4 MΩ
±(1.5% + 10)
40 MΩ
±(2.0% + 8)
Accuracy
±(3,9% + 13)
±(3,9% + 7)
±(5,2% + 7)
Accuracy
±(0,1% + 5)
Resolution
0.001 V
0.01 V
Accuracy
VC290
±(1,5% + 10)
±(1.3% + 3)
±(1,6% + 3)
±(2,0% + 5)
VC290
VC270
0.001 Hz – 0.01 MHz
Resolution
0,1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Resolution
0.01 nF
0.1 nF
0.001 µF
0.01 µF
0.1 µF
Resolution