VOLTCRAFT IPC-1 Notice D'emploi page 17

Masquer les pouces Voir aussi pour IPC-1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The estimated time of charging by various charging current is tabulated in Table 1.
Table 1. Charging Time with various charging current
Size of battery
Battery Capacity
AA
AA
AAA
Note:
User shall always observe the recommended maximum charging current of the
rechargeable batteries. In general, 200 mA is a recommended charging current if rapid
charging is not necessary. It is definitely safe and optimum to the rechargeable batteries.
When the transformer has been plugged to the power source, the version number of the
charger (for example "29" ) will be displayed first. Then all the segments will light up
momentarily and the "null" sign will be shown before batteries are placed. If damaged
batteries are placed to the charging unit, the charger will also show "null" on LCD.
START CHARGING THE RECHARGEABLE BATTERIES
Once a rechargeable battery is inserted after the transformer has been plugged to the power
source, the battery voltage (for example, "1.39V") will be displayed for 4 seconds. Then "200
mA Charge" (default mode) will be shown on LCD for another 4 seconds, indicating that
charging with 200 mA is to be started if no alternation in setting is made.
Within this 8-second time from inserting the batteries the user may first select the
operating mode by the MODE key.
Then within 8 seconds from the last key pressing, user may select the charging/
discharging current by pressing the CURRENT key.
Charging current selected (mA) Estimated charging time
2300 mAh
2000 mAh
700 mAh
"null" displayed - No battery or damaged battery is
placed to the charging unit
1800
1500
1000
700
500
200
1800
1500
1000
700
500
200
700
500
200
~75 min
~90 min
~2 hr 15 min
~3 hr 15 min
~4 hr 30 min
~11 hr 30 min
~70 min
~80 min
~2 hr
~3 hr
~4 hr
~10 hr
~60 min
~84 min
~3 hr 30 min