Hatco HBG Série Manuel D'installation Et D'utilisation page 13

Plaques chauffantes en vitrocéramique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
Changing the Setpoint Temperature — Digital
Temperature Controller
Units equipped with a digital temperature controller will heat up to
the setpoint temperature automatically when they are turned on.
Use the following procedure to change the setpoint temperature.
NOTICE
Built-in units must not have a setpoint temperature higher
than 200°F (93°C). Temperatures exceeding 200°F (93°C)
will damage unit and void warranty.
NOTE: The temperature shown on the display may be inaccurate
when unit temperature is below 130°F (54°C).
1. Press the
key three times. The current setpoint
temperature will be shown on the TEMPERATURE display
("SP" will be shown after the second press).
2. Press the
key or
the setpoint temperature.
3. Press the
key to lock in the new setpoint temperature.
The TEMPERATURE display will go blank for two seconds
to show that the new setting has been accepted.
NOTE: After 10 seconds of inactivity during the programming
process, the controller will exit programming mode
automatically without saving any changes.
5-7/8"
(149 mm)
6-7/8"
(173 mm)
3-7/8" (98 mm)
Front View of Cutout
Form No. HBGM-0120
key within 10 seconds to change
IMPORTANT NOTE:
Make sure the installation
location provides enough
room for electrical connections
to the control box.
6-3/8"
(162 mm)
Flush Mount Control Box Installation Dimensions
OPTIONS AND ACCESSORIES
Up Arrow
SET Key
Digital Temperature Controller
Changing Fahrenheit and Celsius Setting — Digital
Temperature Controller
Use the following procedure to change between Fahrenheit and
Celsius on the display.
1. Press the
key once. Either an "F" for Fahrenheit or "C"
for Celsius will be shown.
2. Press the
key or
between "F" (Fahrenheit) and "C" (Celsius).
3. Press the
key three times to lock in the new setting.
The TEMPERATURE display will go blank for two seconds
to show that the new setting has been accepted.
NOTE: After 10 seconds of inactivity during the programming
process, the controller will exit programming mode
automatically without saving any changes.
Trim Cover
Side View of Installed Control Box
13
Key
Down
Arrow
Key
Display
key within 10 seconds to change
4-3/4"
(121 mm)
Control Enclosure
Mounting Surface

Publicité

Chapitres

Table des Matières
loading

Table des Matières