OPTIONS AND ACCESSORIES
3. At each corner of the base, remove the foot screw and
rubber foot.
Installing the 102 mm (4") Legs
4. At each corner of the base, screw a 4" (102 mm) leg into
the bottom of the base.
NOTE: The feet on the 4" (102 mm) legs are adjustable for
leveling the unit. Use a 5/8" (16 mm) open-end wrench
to make leveling adjustments once the unit is placed in
its final position.
Handle
Handle Installation
Flush Mount Control Boxes
(HBGB Models)
A flush-style remote-mounted control box is available as a
factory-installed option for the HBGB unit.
WARNING
ELECDTRIC SHOCK HAZARD: The remote mounted
control box must be mounted on a vertical wall and
installed in the vertical position. Mounting the control box
in the horizontal position may result in the collection of
liquids and lead to an electric shock.
NOTICE
The remote-mounted control box should be installed
outside of the heat zone. Locating the control box inside
the heat zone will cause the control(s) to overheat,
malfunction, and fail.
4" Leg
Support
Ring
Stud
Nut
Do not modify wiring or cut thermostat capillary wire on
control box to increase remote mounting distance. Cutting
the thermostat capillary wire will cause the unit to overheat
and may damage the unit as well as the surrounding
countertop.
Installing the Control Box
NOTE: A qualified electrician is recommended for installing the
flush mount control box.
1. Prepare cutout and pre-drill screw holes.
2. Remove trim cover from control box assembly.
3. Position control box into opening through the backside.
4. Secure control box to surface using screws (not supplied).
5. Reinstall the trim cover.
6. Plug the control box into a properly grounded electrical
receptacle of the correct voltage, size, and plug
configuration. Refer to the SPECIFICATIONS section for
details.
NOTE: Units are equipped with a 3' (914 mm) flexible conduit
connecting the control enclosure to the unit. The digital
temperature controller also offers 6' (1829 mm) and 10'
(3048 mm) conduit lengths.
Power I/O (on/off) Switch
Both flush-style remote mounted control enclosures are
equipped with a Power I/O (on/off) switch. Move the Power
I/O (on/off) switch to the I (on) position to turn on the unit. The
indicator light in the switch glows when the unit is on.
Changing the Setpoint Temperature — Mechanical
Temperature Control
Turn the temperature control clockwise to increase the setpoint
temperature. Turn the temperature control counterclockwise to
decrease the setpoint temperature.
Temperature Control
Power I/O (on/off) Switch
Mechanical Temperature Control
12
English
NOTICE
Form No. HBGM-0120