ENGLISH
1) GENERAL OUTLINE
The Q.BO TOUCH is a 10-channel transmitter. Each
channel is associated with a code to be typed on the
keyboard.
The transmitter is powered by batteries, therefore
no wired electrical connection is needed. The Q.BO
TOUCH is provided with touch keys; for any operation,
it must be activated by means of the ON key. It can
manage up to 100 different CODES (each CODE con-
sists of a sequence of min. 4 and max. 7 figures) and up
to 10 different activation CHANNELS, each CHANNEL
SIGNAL INDICATIONS
Signal Heard
1 Short beep
1 Long beep
3 Short beeps
RED led fixed after the correct code is entered
RED indicator LED
green indicator LED
ON and function key
Key to confirm operation
Numerical keypad
2) TECHNICAL SPECIFICATIONS
Batteries
Working temperature:
No. of channels:
Frequency:
Transmission:
Range:
Degree of protection:
Dimensions
(*) The range can be affected by environmental and
installation conditions.
8 -
Q.BO TOUCH
INSTALLATION MANUAL
2X CR123A min.1400mAH
-10 +55 °C
10
433.92 MHz
Rolling Code
100m in open field (*)
IP55
Fig. A
corresponding to a different control unit installed (e.g.
sliding gate opening with channel 1 and overhead
door opening with channel 2). The Q.BO TOUCH has a
sensor which, in case of poor light, activates keyboard
lighting to make it easier to enter the code.
For reasons of system safety, in order to add an ena-
bled code, it is necessary to enter a password (default
1234). Such password can be changed and must be
remembered by the user.
WARNING: Keep the anti-tamper Allen key provided
in the kit.
Indicates that a key has been pressed
Code entered correct/ memorisation on control unit
Code incorrect/error
Battery exhausted
3) INSTALLATION
WARNING: think carefully about the installation site.
Structures made from ferrous material could have an
adverse effect on the Q.BO TOUCH's operation.
-------------------------------------------------------------------
4) MEMORIZING ON CONTROL UNIT/RECEIVER
(Fig.C points 1-5).
To control a number of control units separately, use a dif-
ferent channel for each, entering the default codes.
Once that is done, change the codes.
-Change 1111 to 56561
-Change 2222 to 56562
-Change 3333 to 56563
This makes it easier to remember the code as 5656 fol-
lowed by the function number (1 for sliding gate, 2 for
overhead door A, 3 for overhead door B), therefore:
-ON -> 56561 OK -> opens the sliding gate
-ON -> 56562 OK -> opens overhead door A
-ON -> 56563 OK -> opens overhead door B
5) TOTAL DELETION OF CODES (Fig.D points 1-5)
Following the total deletion of all codes, Q.BO TOUCH will
need to be memorized again on the control unit.
Meaning
(Fig.B points 1-6)