6.4 - DIP1 function
AUTOMATIC CLOSURE
If enabled after complete opening, it remains open for a time set with TR1 from 1 Sec
to 120 Sec.
6.5 - DIP2 function
STEP-BY-STEP The SBS function is subordinate to the setting of the DIP3.
The SEQ function is the equivalent of the SBS function. If DIP 2=OFF then the SBS
command executes: open-stop-close-stop-open. If DIP2=ON then the PP command
executes: open-close-open.
6.6 - DIP3 function
CONDOMINIUM FUNCTION
An SBS opening command brings the gate to full opening, no other command is
considered (except for the STOP command that blocks the automation). A closing SBS
command behaves normally: if DIP2 is set to OFF it executes the STOP - OPEN ALL
command, if DIP2 is set to ON it executes the OPEN ALL command.
6.7 - DIP4 function
OUTPUT P.OUT 24Vdc
IF SET TO OFF, A 24V LIGHT IS CONNECTED:
- It flashes slowly if the motor is in the opening movement.
- It flashes quickly if the motor is in the closing movement.
- Steady light on if the motor is stopped and not in closing.
IF SET ON ON:
Perform the photocell test
6.8 - DIP5 function
INPUT STOP
If set on OFF ► STOP input (NC)
IF set on ON ► 8K2 edge safety input
6.9 - DIP6 function
OUTPUT FLASH
If set to OFF it flashes during movement.
If set to ON, it remains on during movement and for the next 10s.
6.10 - DIP7 function
SLOWING SPEED
Determines the slowing speed.