Installing the battery isolating switch and
connecting the battery
Install the battery isolating switch at a suitable position (near
the battery) in the positive line between the battery and the
control unit.
– Make a Ø 25 mm hole.
– Turn the key anticlockwise as far as it will go, and then
remove.
– Insert isolating switch into the hole and fix with suitable
screws, depending on undersurface.
– Split the positive line from the battery, and attach (crimp)
the cable shoes (not included in set) onto the two bare cable
ends.
– Re-insert the key and switch to "OFF". Screw the cables to
the battery isolating switch with the tubular cable shoes.
Perform the rest of the installation as shown in the instal-
lation instructions supplied with your device.
24
Ø 25 mm
+ Control unit
Mover
Fig. 4: Installation of battery isolating switch
Control unit
+
Mover
Battery
Fig. 5: Battery connections
OFF
ON
Remove /
insert key
+ Battery
Battery isolating switch