– Attach the temperature sensor supplied to the battery
casing, near the positive terminal. To do this, remove the
protective film from the self-adhesive Velcro strip (with the
recess) and press this firmly onto the desired position on
the battery. Position the sensor in the middle of the recess
and fix it in place with the second Velcro strip. Connect the
cable of the temperature sensor to the temperature sensor
connection of the device (2-pole connection).
Fig. 3: Assembly of the temperature sensor
– When the device is delivered, it is set to operation with liq-
uid electrolyte batteries. If necessary, you can set a different
battery type (liquid or gel / AGM) using the toggle switch.
– Connect the mains cable to the power distribution of your
boat, mobile home or caravan. Connect the green / yellow
cable to the earth circuit!
– Check that all the connections are firm and secure.
– Finally, connect to the mains using the rubber 230 V mains
plug of the power cable.