Télécharger Imprimer la page

Health O Meter PRO PLUS 2101KL Mode D'emploi page 30

Masquer les pouces Voir aussi pour PRO PLUS 2101KL:

Publicité

Les langues disponibles

Les langues disponibles

Request
Q
Name
ESC
character
Response
P
Diagnostics(1)
A
Diagnostics(2)
Z
Control (set a
C
value)
Get subject
G
record data and
readings
Set subject record
S
data
Clear readings
X
Clear subject
Y
record data
Name of Control
Auto Hold Time
Auto Off Time
Sleep Time
Keypad Volume
Stable weight Volume
Alarm Volume
Display of Date/Time
Backlight
Contrast
Weight
Display
decimals(d) or Pounds and ounces (p)
Tare Weight
Unit Of Measure (Metric or constitutional)
Positions left in RAM
Table A - Scale Global Values List and Identifiers
Name of component to test
Load Cell A
Load Cell B
Load Cell C
Kbytes or Bytes) and send the data.
Qccc
This is a request to receive scale global values such as
brightness of LCD, auto hold time, keypad beep volume, etc.
(See Table A) (i.e. <ESC>QAHT will return the Auto Hold Time
of 10 seconds like this: <ESC>PAHT=10<ESC>E )
ESC value with
parameters
Pccc=ccccccc This will be the scales response to the request mentioned above
Accc
This is the request for a diagnostic test on certain parts of the
scale (such as battery life, loadcells, keypad, LCD etc.). (See
Table B)
Zccc
This will be the response of the diagnostics done on the scale.
Values will include error codes to indicate what is wrong with the
scale, or all zeros to indicate that all is well.
Cccc=cccccc
This is to set the value of the scale's global settings such as
backlight, auto hold time, keypad beep volume etc. (See Table
A) (i.e. <ESC>CAHT=20<ESC>E will set the Auto Hold Time to
20 seconds)
G
This will return all the information from both the subject record
data as well as the readings stored in the readings table.
This will set the subject record data for a specific patient.
S
Immediately following this will be the value that is set. (i.e.
<ESC>S<ESC>I1234<ESC>T200<ESC>Um<ESC>E will set
the TARE for patient ID1234 to 200kg)
X
This will clear all the values stored in the readings table on the
scale. Only the subject record data will not be deleted.
This will clear the subject record data for a specific patient. The
Y
patient ID will follow the Y immediately (<ESC>Iccccccccccc). If
no ID is given, ALL the data will be cleared.
Mode
(fractions(f),
Identifie
r
LCA
LCB
LCC
Description
Identifier
Unit
AHT
nn (Seconds)
AOT
nn (Minutes)
STM
nn (Seconds)
VKE
nn (01..10)
VSW
nn (01..10)
VAL
nn (01..10)
DAT
nn (01 or 10)
BAC
nn (01..10)
CON
nn (01..10)
WDM
c (f,d,p)
TAR
nnn.nn (Kg)
UOM
c (m or c)
RAM
nnnn (0..max)
Error Code
E3A
E3B
E3C
29

Publicité

loading

Ce manuel est également adapté pour:

Pro plus 2500klPro plus 2600kl