Troubleshooting and fault elimination
Display
MASTER DAMAGED!
MASTER MISSING
INVALID MASTER!
NAME EXISTS!
MEMORY FULL
TRANSFER FAILED
INVALID OPTION!
INVALID EPM!
NO FILES
CFG EPM MISSING!
Cause
The EPM in the MASTER PORT is
defective.
The EPM is not placed correctly in the
MASTER PORT.
Seen on power-up if there is no EPM
in the MASTER PORT.
Programmer is trying to read data
from the MASTER PORT but cannot
detect an EPM in this PORT.
The EPM you are attempting to read in
the MASTER PORT is defective or has
no valid data.
The EPM in the MASTER PORT is a
Configuration EPM.
The file name you want to allocate to a
parameter file already exists.
The internal memory of the EPM
programmer is full.
Error in the data transmission to the
EPM PORT, because the memory chip
is defective, or is not placed correctly
in the PORT.
Attempted MASTER -> EPM transfer
when- the memory size of the
MASTER EPM is different from that
of the target.
Error in the data transmission to the
EPM PORT, because of an internal
error in the EPM programmer.
Attempted to CREATE a new file from
a servo drive EPM in the MASTER
PORT.
Attempted to EDIT a non-servo EPM
or a corrupted servo EPM.
Attempting to EDIT, DELETE or
CREATE a file, but there are no stored
files in the EPM Programmer.
Attempt to LOAD CFG EPM without
a valid configuration EPM in the
MASTER PORT.
ENGLISH
Remedy
Press the menu key to return to the
main menu.
Plug an EPM in the MASTER PORT.
The message does not indicate an
error but only serves as a note.
The message is only displayed for a
short time.
Information only.
Insert a valid EPM into the MASTER
PORT.
Press the menu key now to return to
the main menu.
Exchange the EPM in the MASTER
PORT.
A Configuration EPM cannot be
copied.
Select another file name.
It is not possible to save any more
parameter files.
If necessary, delete parameter files
you do not need anymore.
Exchange the defective EPM or plug
the EPM correctly in the PORT.
Replace the EPM in the EPM PORT
with an EPM of the same color as
the Master.
Please contact your Lenze
representative.
Only inverter drive EPM's can be
saved as files in the EPM Programmer.
Replace the EPM in the EPM PORT
with a valid servo EPM.
Insert a configuration EPM into the
MASTER PORT.
21