Clearances
The following minimum safety clearances from materials or
objects in the surroundings of the heater must be ensured:
Sides 30 in.
Top
80 in.
• Floors and ceilings must be made of fireproof materials
in the room where the heater is operated
• The air inlet and outlet must never be blocked for any
reason.
• Install the heater on a flat , level floor in a steady
position.
• It is forbidden to connect direct-fired heaters to air
ducts.
WARNING
• DO NOT USE GASOLINE, NAPHTHA OR VOLATILE
FUELS.
• STOP HEATER BEFORE ADDING FUELS.
• ALWAYS FILL OUTDOORS AWAY FROM OPEN FLAME
• DO NOT USE EXTERNAL FUEL SOURCE.
• DO NOT OPERATE HEATER WHERE FLAMMABLE
LIQUIDS OR VAPORS MAY BE PRESENT.
• DO NOT START HEATER WHEN CHAMBER IS HOT
• DO NOT START HEATER WHEN EXCESS FUEL HAS
ACCUMULATED IN THE CHAMBER.
• DO NOT PLACE COOKING UTENSILS ON TOP OF THE
HEATER.
• PLUG ELECTRICAL CORD INTO A PROPERLY
GROUNDED THREE-PRONG RECEPTACLE.
STARTING THE HEATER
The heater can only work automatically when a control
device, such as a thermostat or a timer, is connected to the
heater. Connection to the heater is made by removing the
socket cover(4) and inserting the thermostat plug. To start
the machine you must:
• If connected to the thermostat, turn the switch to
(ON + ) the down position.
• If not connected to the thermostat, turn the switch to
(ON ) the up position.
When unit is started for the first time or is started after
the oil tank has been totally emptied, the flow of oil to the
burner may be impaired by air in the circuit. In this case
the control box will cut out the heater and it might be
necessary to restart the starting procedure once or twice
by depressing the reset button (1).
Should the heater not start, check that oil tank is full and
depress reset button (1).
Should the heater still not work, please refer to the trouble
shooting section of this manual.
Fuel Fired Portable Radiant Construction Heater
Air Inlet 30 in.
Air outlet 40 in
RESET BUTTON
This heater is equipped with an internal diagnostics system.
Should the heater not start for any reason the reset switch (1)
will illuminate. In order to observe the diagnostic blinks you
have to depress the reset button for 10 seconds. The light will
then generate a series of blinks that will indicate why the heater
entered a fault mode. Refer to the chart below for the list of
fault codes.
2-BLINKS Heater failed to start
4-BLINKS Photocell shutdown (lack of light)
5
6-BLINKS Loss of flame during operation
*Refer to Troubleshooting for solutions.
STOPPING THE HEATER
Set main switch (3) on "0" position or turn thermostat or other
control device on lowest setting or to a temperature lower than
that of the room it resides.
The flame goes out and the fan continues to work for approx.
90sec. cooling the combustion chamber.
SAFETY DEVICES
This heater is equipped with an overheat thermostat safety
cutout which will stop the heater in case of overheating. This
thermostat will reset automatically but you will have to depress
button (1) on control box before being able to restart the
heater.
WARNING
Before making any attempt to restart the heater find
and eliminate the reason

TRANSPORT

Before heater is moved it must be stopped and unplugged.
Before moving the heater wait till it has totally cooled off and
make sure oil tank cap is securely fixed.
MAINTENANCE
Preventive and regular maintenance will ensure a long trouble
free life to your heater.
WARNING
• Never service heater while it is plugged in, operating or
hot. Severe burns or electrical shock can occur.
Every 50 hours of operation: disassemble the filter and wash
with clean oil, remove upper body parts and clean inside and
ventilator with compressed air, check for the correct attach-
ment of the connectors to the electrodes and check all cables,
remove burner assembly, clean and check electrode settings,
adjust according to figure
"Electrode Gap".
5
Operating Instructions and Owner's Manual

Publicité

Table des Matières
loading

Table des Matières