Pre-Operation; Amperage Range - Speedaire 15D802 Consignes D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Speedaire Operating Instructions & Parts Manual
Speedaire Gasoline Air
Compressor, Generator
and Welder

PRE-OPERATION

Check the engine oil level before start-
ing. (See engine manual.) Fill the fuel
tank according to the engine manual
instruction.
Pump oil level should be checked
before each use. Check the oil levelin-
E
dicator on the pump crankcase. Make
N
certain the oil is in the center of theoil
G
sight glass. If the level appears to be
L
low, fill with SAE20 or 30 non-deter-
gent pump oil.
I
Remove any moisture in the unit's air
S
tank. NEVER attempt to open the Air
H
Tank Drain Valve when more than 10
PSI of air pressure is in the air tank!
emove excessive pressure with an air
tool, then open the Air Tank Drain
Valve in the bottom of the air tank.
Close tightly when drained.
Make sure the Engine Switch is in the
"OFF" position.
Make sure the Safety Relief Valve is
working correctly.
Make sure all guards and covers are in
place and securely mounted.
OPERATION
Read safety warnings before perform-
ing operation.
Make sure the unit is grounded. See
Grounding Instructions.
NOTE: Unplug all equipment from the
power receptacles before starting the unit.
Flip the toggle on top of the Pilot Valve
to the upright position. This provides a
loadless start. The unit will unload and
allow easier engine start-up.
Start the engine. (Refer to the Engine
Manual accompanying this unit.)
When the engine has run for 1-2 min-
utes, flip toggle back to the original
position.
Set pressure by adjusting the Pressure
Regulator counterclockwise for less pres-
sure and clockwise for more pressure.
Ensure breakers are in on position.
Test the GFCI receptacle(s) on the unit.
Push the test button. The reset but-
ton should pop out and there should
be no power at the receptacle. Apply
a test load or lamp to each recep-
tacle to verify. IF THE RESET BUTTON
DOES NOT POP OUT, DO NOT USE THE
RECEPTACLES(S). SEE DEALER FOR SER-
VICE IMMEDIATELY.
For Warranty and Service Call:
1-800-648-8478
®
If GFCI receptacle(s) test correctly,
firmly push the reset button to re-
store power. A distinctive click should
be heard or felt when this is com-
plete. IF THE RECEPTACLE(S) DO NOT
RESET PROPERLY, DO NOT USE THE
RECEPTACLE(S). SEE DEALER FOR SER-
VICE IMMEDIATELY.
Turn idle control switch to AUTO-IDLE
DOWN position.Loads can now be ap-
plied to the unit.
WELDING START-UP:
1.
Remove all AC electrical loads from
the unit.
2.
Move GEN/WELD switch to WELD
position.
3.
Position selector switch and min/
max switch for amperage setting.
4.
Move idle control to full throttle
setting.
5.
Check grounding.
6.
Welding Cable Diagram (Selecting
Weld Cable Sizes)*:
and Total Cable (Copper) Length in Weld Circuit Not Exceeding***
100 ft (30
150 ft
m) or Less
(45 m)
Welding
Amperes
100% Duty
Cycle
100
4 (20)
4 (20)
150
3 (30)
2 (35)
* This chart is a general guideline and may not suit all applications. If cable over-
heats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current
density of at least 300 circular mils per ampere ( ) = mm2 for metric use.
***For distances longer than those shown in this guide, call a representative.
Do not use worn, damaged, under-
sized, or Poorly spliced cables. Turn
off power before connecting to
weld output terminals.
NOTE: This engine is equipped with a
"Low Oil" shutdown system for engine
protection. The engine stops whenthe oil
level gets too low. The engine will not
restart without adding oil.
6

AMPERAGE RANGE

3/32
6010
1/8
and
5/32
6011
3/16
1/16
5/64
3/32
6013
1/8
5/32
3/16
3/32
1/8
7014
5/32
3/16
3/32
1/8
7018
5/32
3/16
Weld Output Terminals
Weld Cable Size**
200 ft
250 ft
300 ft
(60 m)
(70 m)
(90 m)
10 − 100% Duty Cycle
3 (30)
2 (35)
1 (50)
1 (50)
1 (50)
2/0 (70)
If you notice any unusual noise or
vibration, stop the unit and refer to
"Troubleshooting".
SHUTDOWN
1.
Remove all load by turning off
electrical appliances and unplug-
ging electric cords.
2.
Move the Engine Switch to the
"Off" position. (Refer to the
Engine Manual accompanying this
unit.)
15D802
350 ft
400 ft
(105 m)
(120 m)
1/0 (60)
1/0 (60)
3/0 (95)
3/0 (95)

Publicité

Table des Matières
loading

Table des Matières