Adjusting the telescopic suction pipe
Illustration
If the device is parked in the parking position, first
release the parking position.
In order to do this, hold the floor nozzle still with
your foot and tip the device backwards slightly.
Hold the button down and adjust the suction pipe to
the desired length.
Setting the vacuum cleaning performance
Illustration
Note
Press the buttons for suction performance to individual-
ly set the suction power.
Stage 1: Low performance range
For vacuuming sensitive materials and light com-
ponents, such as upholstered furniture, rugs, cush-
ions, curtains, etc.
Stage 2: Medium performance range
For daily vacuuming of lightly soiled surfaces and
for cleaning low-pile carpets.
Stage 3: High performance range
For vacuuming durable floor coverings, hard floors,
high-pile carpets and heavily soiled surfaces.
IMPORTANT NOTE! The device shuts off automatically
if there is a danger of overheating. Make sure that the
nozzle or suction pipe is not blocked and check if the fil-
ter needs to be changed. After remedying the malfunc-
tion, let the device cool down for at least 1 hour, after
that the device will be ready for use again.
Reversible floor nozzle
Illustration
Hard surfaces
Parquet nozzle
Depending on equipment
Illustration
Used to vacuum sensitive and smooth floors (par-
quet, marble, terracotta etc.).
Using accessories
Depending on equipment
Illustration
Upholstery nozzle: for cleaning upholstered furni-
ture, mattresses, laced curtains, etc.
Crevice nozzle: for edges, joints and heaters
Furniture brush: for gentle cleaning of furniture
and delicate objects, such as books, etc.
Finish operation
Illustration
Transport, storage
Illustration
Engage the device (telescopic pipe is not extend-
ed) in parking position on the floor nozzle.
The device can also be stored in a horizontal posi-
tion, for example on a shelf on in a cupboard.
Note
Store the appliance in a dry room.
Carpets / carpeted
floors
Care and maintenance
Emptying the main filter
Recommendation: Empty main filter after every use.
For rest of procedure see:
Figure
to
Note
When you unscrew it, the filter is automatically
cleaned and the dirt is removed.
Emptying long life filter
Recommendation: Remove, empty and (if necessary)
clean long-life filters no later than every 2 months.
ATTENTION
The amount that can be vacuumed up can vary depend-
ing on the vacuuming material.
For fine dust, in particular, emptying may be necessary
earlier.
In order to ensure good filtration, replace long life filter
with new filter every 2 years.
For rest of procedure see:
Figure
to
Notes
When you unscrew it, the filter is automatically
cleaned and the dirt is removed.
Reinsert the long life filter in the filter box according
to the marking and screw it in completely until the
red safety rod is no longer visible.
ATTENTION
If the red safety rod is still visible, the filter box can-
not be inserted into the device.
The filter lock must therefore be screwed in all the
way.
Only install dry long life filters in the device.
Replacing exhaust filter
Recommendation: In order to ensure good filtration,
replace the exhaust filter once a year.
Illustration
Remove the exhaust filter cover upwards at an an-
gle along the edge of the device.
Press the exhaust filter together on both sides and
remove.
Attach a new exhaust filter and lock in place.
Place the exhaust filter cover on the edge of the ap-
pliance, push it downwards and lock in place.
Troubleshooting
Declining suction performance or the device automati-
cally switching off due to overheating can be caused by:
Blockage in accessories: Remove the blockage
carefully with a narrow tool.
Illustration
Blockage in telescopic suction pipe: Lever the cov-
er on the handle off with a screwdriver and then re-
move the blockage carefully with a narrow tool.
Check to see whether the filters are intact or dam-
aged.
See chapter "Care and Maintenance".
– 6
EN