Codes d'erreurs
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SERIES:
OUTDOOR UNIT MAXI MVD V5X (2 pipes)
MVD-V5X252W/V2GN1
UNITS:
MVD-V5X280W/V2GN1
MVD-V5X335W/V2GN1
MVD-V5X400W/V2GN1
MVD-V5X450W/V2GN1
Error
Content
code
E0
Communication error between outdoor units
E1
Phase sequence error
E2
Communication error between indoor units and the master unit.
E3
Reserved
E4
Malfunction of outdoor ambient temperature sensor (T4)
E5
Malfunction of power supply voltage
E6
Reserved
E7
Malfunction of discharge temperature sensor
E8
Faulty outdoor unit address
xE9
Driver model is mismatched
Malfunction of communication between main control chip and inverter
xH0
driver chip
Malfunction of communication between main control chip and
H1
communication chip
H2
Outdoor unit quantity is decreased
H3
Outdoor unit quantity is increased
xH4
Inverter module protection
H5
P2 protection appears three times in 60 minutes
H6
P4 protection appears three times in 100 minutes
H7
Faulty indoor units quantity
H8
Malfunction of pressure sensor for discharge pipe
H9
P9 protection appears three times in 60 minutes
Hc
Reserved
F0
PP protection appears three times in 150 minutes
C7
PL protection appears three times in 100 minutes
yHd
Slave units malfunction
P0
Temperature protection of inverter compressor
P1
High pressure protection
P2
Low pressure protection
xP3
Over current protection of compressor
P4
Discharge temperature protection
P5
Condenser high temperature protection
P9
Fan module protection
PL
Temperature protection of inverter module
PP
Insufficient overheat degree protection of compressor discharge
xL0
Inverter module error
xL1
DC generatrix low voltage error
xL2
DC generatrix high voltage error
xL3
Reserved
xL4
MCE error/ synchronization/ closed loop
xL5
Zero speed protection
xL6
Reserved
xL7
Phase sequence error
xL8
Frequency difference in one second more than 15Hz protection
Frequency difference between the real and the setting frequency more
xL9
than 15Hz protection
r1
Refrigerant amount is slightly insufficient
r2
Refrigerant amount is significantly insufficient
r3
Refrigerant amount is critically insufficient
R1
Refrigerant amount is slightly excessive
R2
Refrigerant amount is critically excessive
(CL23300 to CL23307)
(CL23300)
MVD-V5X500W/V2GN1
(CL23301)
MVD-V5X560W/V2GN1
(CL23302)
MVD-V5X615W/V2GN1
(CL23303)
OUT. UNIT MUCHR-H6A
(CL23304)
OUT. UNIT MUCHR-H8A
92
TROUBLESHOOTING
(CL23305)
(CL23306)
(CL23307)
(CL23907 to CL23910)
(CL23920 to CL23923)
Note
Only display on the faulty slave unit
Display on the faulty unit
Only display on the master unit
/
Display on the faulty unit
Display on the faulty unit
/
Display on the faulty unit
Display on the faulty unit
When x is 1, it means A system; 2 means B
system
Display on the faulty unit
Display on the faulty unit
Only display on the master unit
Only display on the master unit
Display on the faulty unit
Cannot be recovered until re-power on
Display on the faulty unit
Cannot be recovered until re-power on
Display on the faulty unit
Cannot be recovered until re-power on
Display on the master unit
Cannot be recovered until unit quantity
recover
The
discharge
(43.5PSI)
Display on the faulty unit
Cannot be recovered until re-power on
/
Display on the faulty unit
Cannot be recovered until re-power on
Display on the faulty unit
Cannot be recovered until re-power on
Y stands for corresponding slave unit, y=1,
2, 3.
Display on the faulty unit
Display on the faulty unit
Display on the faulty unit
Display on the faulty unit
Display on the faulty unit
Display on the faulty unit
Display on the faulty unit
Display on the faulty unit
Display on the faulty unit
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
EN
pressure

Publicité

Table des Matières
loading

Table des Matières