mundoclima 2022 Manuel page 66

Codes d'erreurs
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SERIES:
MULTISPLIT - H3M
MULTISPLIT - H3M
UNITS:
MUEX-14-H3.2 / MUEX-18-H3.2
MUEX-24-H3.3 / MUEX-28-H3.4
Code
U8
Zero cross detection circuit malfunction
C5
Malfunction protection of jumper cap
H6
Feedback of without IDU motor
F1
Indoor ambient temperature sensor is open/short circuited
F2
Indoor evaporator temperature sensor is open/short circuited
b5
Liquid valve temperature sensor is open/short circuited
b7
Gas valve temperature sensor is open/short circuited
P7
Modular temperature sensor is open/short circuited
F4
Outdoor ambient temperature sensor is open/short circuited
A5
Outdoor condenser inlet pipe temperature sensor is open/short circuited (commercial)
F4
Outdoor condenser middle pipe temperature sensor is open/short circuited
A7
Outdoor condenser outlet pipe temperature sensor is open/short circuited (commercial)
F5
Outdoor discharge pipe temperature sensor is open/short circuited
E6
Communication malfunction
U1
Malfunction of phase current detection circuit for compressor
HE
Compressor demagnetization protection
U3
Malfunction of voltage dropping dor DC bus - bar
P8
Module high temperature protection
F0
Refrigerant lacking or blockage protection of systen (not avalaible for residential ODU)
PU
Charging malfunction of capacitor
E1
High pressure protection of system
E3
Low pressure protection of system (reserved)
H3
Compressor overload protection
LP
Indoor unit and outdoor unit do not match
EE
Malfunction of memory chip
dn
Wrong connection of communication wire or malfunction of electronic expansion valve
U5
Malfunction of complete units current detection
L3
Malfunction protection of outdoor fan 1
Detection status of wrong connection of communication wire
dd
or malfunction of electronic expansion valve
E7
Mode conflict
Fo
Refrigerant recycling mode
AL
X-fan
H1
Defrosting or oil return in heating mode
Lc
Start failure of compressor
E4
High discharge temperature protection of compressor
E8
Overload protection
E5
Whole unit overcurrent protection
P5
Compressor phase current protection
H7
Compressor desynchronizing
Ld
Compressor phase-lacking / phase-inverse protection
H5
IPM modular protection
PL
DC bus - bar low voltage protection
PH
DC bus - bar high voltage protection
HC
PFC protection
U7
The for-way valve is abnormal
(CL20810-838)
(CL20814 / CL20810)
(CL20811 / CL20812)
Description
66
TROUBLESHOOTING
Error Type
Outdoor hardware
Outdoor hardware
Indoor hardware
Indoor hardware
Indoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
System Error
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
System Error
Outdoor hardware
System Error
System Error
Outdoor hardware
System Error
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
System Error
Special Mode
Special Mode
Outdoor hardware
System Error
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
Outdoor hardware
EN
-