CONTROL PANEL
When power is on, the control unit checks that display correctly
operates by switching on all segments for 1.5 sec.
Pr 1.0
Firmware version, e.g.
1.5 sec.
Panel will be viewed upon completion of this test.
OPEN CONTACT
CLOSED CONTACT
MENU
SEL
START
STOP
DOWN
The control panel represents the physical status of the terminal
board contacts and of the program mode keys: if the upper
vertical segment is on, the contact is closed; if the lower vertical
segment is on, the contact is open.
The arrows to the left of the display indicate the status of the
MENU and SEL buttons.
The arrows to the right of the display indicate the status of the
shutter.
• The highest arrow lights up when the shutter is in the opening
phase.
• The central arrow indicates that the shutter is paused.
If it flashes it means that the timer for automatic closing is
active.
• The lowest arrow lights up when the shutter is in the opening
phase.
The display shows the following messages when an operation is
prevented due to an event:
- L2 -
the contact on terminal L2 (STOP) is open
- L5 -
the contact on terminal L5 (PHOTOELECTRIC CELL)
is open
- L6 -
the contact on terminal L6 (EDGE) is open
- L7 -
the contact on terminal L7 (FIRE) is open
- P2 -
the STOP button on the keyboard has been pressed
- r3 -
channel 3 of the receiver (STOP) has been activated
- AU -
the AUX channel on the panel (used by WES-EASY) is
not working
- FS -
the door is already at its limit in the required direction
- 0P -
the operator has stopped the operation by pressing a
button on the control unit
8.8.8.8
, will be viewed in the following
OPENING IN PROGRESS
PAUSE
(GATE OPENED)
CLOSING IN PROGRESS
FIRE
EDGE
PHOTOCELL
PROGRAMMING
The functions of and times of the control unit are programmed
.
via the configuration menu, which can be accessed and explored
using the 2 MENU and SEL keys.
• To access the programming menu, press the MENU key until
the display shows
• To change the value of this parameter, press the MENU key:
the display shows the currently set value (
• Select the desired value with the SEL key and press the MENU
button to save the new value: the display shows
• Press the SEL key to select the other parameters to be changed
Using the MENU and SEL keys to select and change the required
parameters: in the following pages there is a table with all
programming parameters, values selected, DEFAULT values set and
a brief description of the function.
To exit the programming menu, press the MENU key until the
display shows the control panel
If no button is pressed for 30 seconds, the control unit exits
programming mode and stores the new parameters.
To exit the programming menu and undo the changes made
during the current programming session, press the MENU and SEL
keys simultaneously until the display shows the control panel.
To load default data, when the control unit is NOT in
programming mode, press the MENU and SEL keys simultaneously
until the display shows
With the SEL key, select the default that you want to load and
press MENU to confirm.
NOTE: the control unit is supplied with the
set
- 16 -
in 1
on
oFF
/
dEF
.
dEF1
configuration
)
in 1
again