Kenmore 78079 Mode D'emploi page 13

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
Installation Requirements
See Figure 17. Inspect window track, sash, and sill.
Ensure window will bear weight of air conditioner for
extended period of time. Measure width of window
opening to be sure installation kit will fit. Air conditioner
is designed for windows 28" to 42" wide. Ensure lower
left inside corner of window is within 6' of appropriate
electrical outlet.
NOTE: Installation kit is designed for most double-hung
windows that do not have storm windows
installed. If storm window is installed or if
installation is in mobile home, window sill may
need modification. See procedure for Storm
Window Modification or for Mobile Home
Window Modification.
Figure 17. Typical Double-Hung Window
1. Window frame
2. Window track
3. Outdoor sash
4. Indoor sash
5. Window sill (indoor)
1
2
3
4
5
Storm Window Modification
See Figure 18. If storm window frame does not allow
adequate clearance (¼" required) to window sill, remove
frame or create clearance by adding wood strip at 1½"
wide along entire width of sill. Fasten wood strip to sill
with 3 countersunk wood screws (not provided). Use
countersunk screws to ensure a smooth surface for
mounting kit.
Mounting kit can now be installed.
Figure 18. Installing Wood Strip
1. Indoor sash (shown open)
2. Wood strip (1½" wide)
3. Indoor sill
4. Storm window frame
5. At least ¼" clearance between top of window sill and
top of storm window frame
6. Outdoor sash
5
4
13
6
1
2
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

78098700897012978189

Table des Matières