GAS CONNECTION
GAS CONNECTION - NATURAL GAS (NG)
GAS CONNECTION - NATURAL GAS (NG)
To ensure proper heating performance of this appliance, verify that the gas line supply pressure is
adequate. The appliance is supplied with a gas pressure regulator already installed. This regulator
EN
is set for a supply (inlet) pressure of 7-14 inch WC [1.74-3.48 kPa] to maintain 5 inch WC [1.24 kPa]
nominal outlet (manifold) pressure.
Ensure that the service pipe supplying the appliance is fitted with a shut-off valve conveniently
positioned and easily accessible as an emergency gas shut-off.
GAS CONNECTION - LIQUID PROPANE (LP)
GAS CONNECTION - LIQUID PROPANE (LP)
If you purchased an LP version of your appliance, it will be supplied with a gas pressure regulator
already installed. This regulator is set to maintain 10 inch WC [2.49 kPa] nominal outlet (manifold)
pressure. Ensure that the service pipe supplying the appliance is fitted with a shut-off valve
conveniently positioned and easily accessible as an emergency gas shut-off.
When connecting to LP gas, verify the tank is equipped with its own high pressure regulator. The
pressure of the gas supplied to the appliance must be 11-14 inch WC [2.74-3.48 kPa].
LEAK TESTING
LEAK TESTING
GENERAL
Although all gas connections on your Hestan appliance are leak tested at the factory prior to
shipment, a complete gas tightness check must be performed at the installation site due to possible
movement in shipment, or excessive pressure unknowingly being applied to parts of the unit.
Immediately check if the smell of gas is detected. Leak testing of the appliance shall be conducted
according to these instructions:
BEFORE TESTING
DO NOT SMOKE WHILE LEAK TESTING.
DO NOT SMOKE WHILE LEAK TESTING.
•
Never leak test with an open flame.
•
Make a soap solution of one part liquid detergent and one part water for leak testing purposes.
•
Apply the solution to the gas fittings and flex hose by using a spray bottle or a brush.
TO TEST
TO TEST
•
Make sure all control knobs are in the "OFF" position.
•
Apply the soap solution to all fittings and flex hose.
•
Turn the gas supply on.
•
Check all connections from the supply line up to regulator connection at the rear of the
appliance.
•
Soap bubbles will appear where a leak is present. If a leak is present, immediately turn off gas
supply, tighten any leaking fittings, turn the gas supply back on, and recheck.
•
If you cannot stop a gas leak, turn off the gas supply and call the dealer where you purchased
your appliance.
•
Do not use the appliance until all connections have been checked and do not leak.
FINAL SETUP
Remove any final packaging materials, and protective film from all exterior areas. Install any loose
items like sealed burner heads, cooking grates, etc. Ensure the sealed burner heads are properly
installed and seated on the burner base as shown below. There are notches on the burner base and
cross ring to help with alignment. The outer burner head features a long slot on the top of the head
which aligns with the spark igniter. Assembly of the single-flow burner head is similar.
10
©2021 Hestan Commercial Corporation
(CONTINUED)