Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The instrument is powered by means of an internal rechargeable battery.
All these functions have been brought together in one instrument weighing only
half a kilo. The ergonomic, sturdy design makes the PROPOWER-5 a working tool
without parallel.
1.2

Specifications

TUNING
Tuning range
Tuning mode
Channel plan
Resolution
Indication
Channel frequency offset
LEVEL MEASUREMENT
Measurement
Digital channels
Measuring range
Maximum input level
From 1 to 50 MHz
Reduction of the measurement range depending on the number of channels.
Up to 10 channels
Readout
IF bandwidth
Input impedance
Audible indicator
Accuracy
Digital channels
DIGITAL SIGNALS MEASUREMENT
Bandwidth
Frequency tuner
CARRIER / NOISE RATIO MEASUREMENT
Measurement
Digital channels
Measurement range
Digital channels
Accuracy
Page 2
USER'S MANUAL. PROPOWER-5
From 1 to 50 MHz.
By channels or by frequency.
10 channel plans, each one with a maximum of 140
channels. Factory start-up channel plans: custom
(1)
under request
.
10 kHz.
Graphic LCD with back lighting.
± 2 MHz (10 kHz resolution).
Power measurement in the channel bandwidth by
integration method.
From -80 to 20 dBm.
(2)
25 dBm
.
10 dBm.
Digital in dBm, dBm/Hz and analogue through a
graphic bar. 1 dB resolution
200 kHz ± 50 kHz
50 Ω
Tone which varies with the signal level.
± 3 dB (from 0 to 40 °C) for 2.5 MHz bandwidth
channels.
Switchable.
10 kHz.
Ratio between the channel power and the noise
level. The frequency where noise is measured is
user definable in absolute or relative value. In the
relative mode, the unit takes as default frequency
offset the value BW/2.
> 30 dB for input level > -40 dBµV.
± 2 dB
07/2006

Publicité

Table des Matières
loading

Table des Matières