The ATEX certificate and product label also carry the following mark:
1180
This signifies unit compliance to the relevant European directives, in this case 94/9/EC, along with the number
of the notified body issuing the EC type examination certificate.
The ATEX and IECEx units also have the following EMC approvals
Electro-static discharge (DC and AC) to EN61000-6-2:2005 / IEC61000-4-2:1995 +A1:1998 & A2:2000
Radiated Field Immunity (DC and AC) to EN61000-6-2:2005 / IEC61000-4-3:2002 + A1:2002
Electrical Fast Transients/Bursts (DC and AC) to EN61000-6-2:2005 / IEC61000-4-4:2004
Surge Immunity (DC and AC) to EN61000-6-2:2005 / IEC61000-4-5:1995 + A1:2000
Conducted Immunity (10V) to EN61000-6-2:2005 / IEC61000-4-6:2005 + A1:2004 & A2:2006
Dips and Interruptions (AC) to EN61000-6-2:2005 / IEC61000-4-11:2004
Conducted and radiated emissions (AC) to EN61000-6-3:2007
Mains harmonics (AC) to EN61000-6-3:2007 / IEC61000-3-2:2006
6.0 SPECIAL CONDITIONS FOR SAFE USE
1. For replacement purposes, the cover fixing screws shall be of stainless steel, minimum grade A4-80
2. Any cable entry device used with the equipment shall be suitable for the entry arrangement and maintain
the ingress protection level IP6X
© Cooper MEDC 2010
12/10