TLGB 20 Set up

Grease low monitoring*

• Flow accuracy is +/- 10% at ambient
temperature 32 °F (0 °C) - 95 °F (+35 °C)
and back pressure 0 psi - 4 000 psi
(0 bar - 275 bar) Precise delivery is not
measured outside these parameters
• Meter accuracy is valid for use with
NLGI 1 and 2 EP Lithium grease
• Resolution of meter is 1 oz and 0 1 g
Install/replace grease
cartridge
1 Loosen grease tube assembly (1) from
pump assembly (9) a few turns, but do not
remove
2 Pull back on follower handle (12) and latch
follower rod groove into slot on
tube cap († ig. 2)
3 Unscrew grease tube assembly (1) from
grease gun
9
1
4 Remove plastic cap from grease cartridge
and insert cartridge into container tube
5 Remove pull tab from grease cartridge
and screw grease tube assembly (1) into
pump assembly (9)
6 Thread grease tube assembly (1) back
onto power head
7 Using follower handle (12), release
follower rod from slot
NOTE
Air pockets in lubricant will cause gun to lose
prime and may cause inaccurate readings
8 Purge air from grease tube by unscrewing
vent valve (8) 2-3 turns until grease lows
from valve († ig. 1, pg. 9)
9 Retighten vent valve (8) Refer to
Expelling air pockets, page 12
* Indicates change
1
10

Prime the grease gun

Prime cordless grease gun after each reill or
grease cartridge change
Priming instructions
Prime cordless grease gun after each reill or
grease cartridge change
1 Open vent valve (8) († ig. 1, pg. 9)
2 Squeeze gun trigger until grease lows
from vent valve
3 Close vent valve
4 Press button "1" (4) for 3 seconds to clear
display of previous reading († ig. 3,
pg. 11)
12