Operation

Display and light

To turn display (5) "on", either:
• Push button "1" (4) († ig. 3)
• Squeeze the trigger/switch
To turn light "on/off":
• Push button "1" (4)
Display and light shut off automatically after
30 seconds if gun is not operating

Speed selection

Pressing button "2" (4) switches the tool
between high and low pump speed
The letter "L" or "h" will be displayed on
the screen
High delivers 160 ml/min (5.5 oz/min.) at
69 bar (1 000 psi) back pressure
Low delivers 100 ml/min (3.5 oz/min.) at
69 bar (1 000 psi) back pressure
Motor speed increases automatically from
"L" to "H" if back pressure exceeds
2 500 psi (172 bar) *

Switching units

Switch units of measure between ounces
or grams by holding button "1" (4) for
15 seconds († ig. 3)
* Indicates change
5
4
4A
Control/monitor grease
application
Refer to the display representations in ig. 4
1 To set display reading to zero, press set
button "1" (4) for 3 seconds († ig. 4A)
2 Squeeze trigger to run and stop the gun at
desired output (0 6 oz Is shown in
ig. 4B)
3 Press button "2" (4) to switch between low
and high († ig. 4C)
4B
11
5
4
4 Press button "1" (4) for 15 seconds to
switch between ounces and grams
(† ig. 4C)
NOTE
Grease meter displays output only if grease
gun is adequately primed