Battery Replacement; Warnings And Errors; Errors - Airzone ZBS BLUEFACE Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Temperature Control. Raise or lower the base set point temperature configured by any Blueface Thermostat (through
remote zones on the Lite settings parameter) in increments of ± 1 C/2 F up to a limit of ± 3 C/6 F using the buttons.
The LEDs indicate the steps above or below the base set temperature.
Once the three-step limit has been reached, the temperature control icons will blink.

Battery replacement

The Airzone Blueface Thermostat will display a battery alert on its screensaver when the battery of a Lite Thermostat is low. To
know the zone of the Lite thermostat running out of battery, press on the warning icon.
To replace the battery, please remove the thermostat from its back plate and then replace the battery (CR2450).
Important: We recommend the use of top-brand batteries. Using low-quality batteries may reduce the duration of use.

WARNINGS AND ERRORS

Errors

On/Off blinking purple quickly. Lite thermostat - control module communication error.
On/Off blinking red quickly. Control module main control board communication error.