Stop. The air-conditioning system will remain switched off regardless of the demand status of any zone, all the
motorized dampers will remain opened.
Airflow control. This parameter is only available when the Think thermostat is configured as main of a zoned system, selects
the control algorithm that best fits the installation. The available options are:
EN
Silence. The fan speed is lower than in standard mode to reduce the noise.
Standard. Set by default. The system automatically regulates the fan speed based on the number of zones calling
EN
for cooling or heating.
Power. The fan speed is higher than in standard mode to increase the flow.
FR
Heating stages. This option is only available if the zone is configured as air+radiant configuration and enables to choose the
stage of the zone. The available parameters are:
IT
Air: Only uses air stage.
Radiant: Only uses radiant air.
PT
Air+radiant: The system combines both stages to reach comfort quickly and efficiently.
Note: For security reasons, the zone will turn off after changing any setting.
DE
Local Ventilation. This option enables the activation
system is not actively cooling or heating any of the zones.
Timer. It is an auto power-off timer of the zone:
Off. Timer is not activated.
30. It activates the timing and switches off the zone after 30 minutes.
60. It activates the timing and switches off the zone after 60 minutes.
90. It activates the timing and switches off the zone after 90 minutes.
Information. This parameter provides information about:
Zone: firmware, zone, association, actuator or communication status.
System: firmware, settings and information about the system controllers.
Devices: displays the elements connected to the system.
Webserver (Only for system 1 Main thermostat): firmware, IP address, gateway, MAC and PIN.
Main zone. This parameter is only available when the Main thermostat of the group is lost. Enables to access and to modify
the operation mode of the group.
16
or deactivation
of the ventilation in the selected zone when the