TECHNICAL SPECIFICATIONS
Supply voltage:
Power consumption:
Mounting height:
Temperature range:
Degree of protection:
Noise:
Applicable directives:
Detection mode:
Technology:
Output:
Test input:
Norm conformity:
TECHNICAL SPECIFICATIONS (CAMERA)
Voltage Regulator
(built into wire harness)
Operating Temperature
Video Output
Image Sensor
Horizontal Resolution
NTSC Output
Sync System
ANSI / AAADM Compliance
Upon completion of the installation or service work, at a minimum, perform a daily safety check in accordance with the minimum
inspection guidelines provided by AAADM. Provide each equipment owner with an owner's manual that includes a daily safety
checklist and contains, at a minimum, the information recommended by AAADM. Offer an information session with the equipment
owner explaining how to perform daily inspections and point out the location of power/operation switches to disable the equipment if
a compliance issue is noted. The equipment should be inspected annually in accordance with the minimum inspection guidelines. A
safety check that includes, at a minimum, the items listed on the safety information label must be performed during each service call.
If you are not an AAADM certifi ed inspector, BEA strongly recommends you have an AAADM certifi ed inspector perform an AAADM
inspection and place a valid inspection sticker below the safety information label prior to putting the equipment into operation.
BEA hereby declares that the IXIO-DT1 is in conformity with the basic requirements and the other relevant provisions of the directives 1999/5/EC,
2006/95/EC and 2006/42/EC.
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 12 405836-001
Angleur, October 2014
The complete declaration of conformity is available on our website: www.bea-pedestrian.be
Only for EC countries: According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)
Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: Tech_Services@beainc.com | Tech Docs: www.beasensors.com
Page 8 of 8
12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10%
< 2.5 W
6.5 ft to 11.5 ft
(local regulations may have an impact on the acceptable mounting height)
-13°F to +131°F; 0-95% relative humidity, non condensing
IP54
< 70 dB
R&TTE 1999/5/EC; MD 2006/42/EC; LVD 2006/95/EC; ROHS 2 2011/65/EU
Motion
Min. detection speed: 2 in/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm
Electro-mechanical-relay (potential and polarity
free)
Max. contact current: 1 A
Max. contact voltage: 30 V DC
Adjustable Holdtime: 0.5 to 9 s
6.6 - 36 VDC (+/- 10%)
6 - 28 VAC (+/- 10%)
-30° to 60° C (RH 95% max)
1.0 (Vp-p) / 75Ω
CMOS
480 TVL
720 (H) x 480 (V)
Inter-Sync
Pierre Gardier, authorized representative and responsible for technical documentation
(to be operated from SELV compatible power supplies only)
Presence
Typical response time: < 200 ms (max. 500 ms)
Active infrared with background analysis
Spot: 2 in x 2 in (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
2
Solid-state-relay (potential and polarity free)
Max. contact current: 400 mA
Max. contact voltage: 42 V AC/DC
Holdtime: 0.3 to 1 s
Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V)
Response time on test request: typical: < 5 ms
EN 12978
EN ISO 13849-1:2008 PL «c» CAT. 2
(under the condition that the door control system monitors
the sensor at least once per door cycle)
IEC 61496-1:2012 ESPE Type 2
EN 16005:2012 Chapter 4.6.8;
DIN 18650-1:2010 Chapter 5.7.4
BS 7036-1:1996 Chapter 8.1
Specifications are subject to changes without prior notice.
All values measured in specific conditions.
Frame Rate
Minimum Illumination
AE Control
Gain Control
Electronic Shutter
S/N Ratio
AWB
75.5816.06 IXIO-DT1 V UL 20161220
30 fps
0.01 LUX
Auto
Auto
1 s ~ 1/10,000 s
>50 dB
Auto