TECHNICAL SPECIFICATIONS

Supply voltage:
Power consumption:
Mounting height:
Temperature range:
Degree of protection:
Noise:
Applicable directives:
Detection mode:
Technology:
Output:
Test/Monitoring
input:
Norm confor-
mity:
BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA
does not guarantee any use of the sensor outside of its intended purpose.
BEA strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-
trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor
system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL 325).
Verify that all appropriate industry signage and warning labels are in place.
BEA hereby declares that the IXIO-ST is in conformity with the basic requirements and the other relevant provisions of the directives
1999/5/EC, 2006/95/EC and 2006/42/EC.
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 12 405836-001
Angleur, October 2014
The complete declaration of conformity is available on our website: www.bea-pedestrian.be
Only for EC countries: According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)
General Tech Questions: Tech_Services@beainc.com | Tech Docs: www.BEAinc.com
Page 8 of 8
12 – 24 VAC ±10%
12 – 30 VDC ±10%
< 2.5 W
6'6" – 11'6"
Sensor: -13 – 131 °F *
0 – 95% relative humidity, non-condensing
IP54
< 70 dB
R&TTE 1999/5/EC
MD 2006/42/EC
PRESENCE
Typical response time: <200 ms (max. 500 ms)
Active infrared with background analysis
Spot: 2" x 2" (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
Electro-mechanical-relay
(potential and polarity free)
Max. contact current: 1 A
Max. contact voltage: 30 VDC
Adjustable Holdtime: 0.5 – 9 s
Specifications are subject to change without prior notice.
Pierre Gardier, authorized representative and responsible for technical documentation
Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
to be operated from SELV-compatible power supplies only
local regulations may impact acceptable mounting height
LCD screen is operational from 14 - 131 °F.
The sensor may still be programmed in colder
temperatures, but with the remote control.
LVD 2006/95/EC
ROHS 2 2011/65/EU
PRESENSE
typical response time: < 200 ms (max: 500 ms)
Active infrared with background analysis
Spot: 2" x 2" (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
Solid-state-relay
(potential and polarity free)
Max. contact current: 400 mA
Max. contact voltage: 42 VAC / VDC
Holdtime: 0.3 – 1 s
Sensitivity:
Low: < 1 V
High: > 10 V (max. 30 V)
Response time on test request: typical: < 5 ms
EN 12978
EN ISO 13849-1:2008 PL «c» CAT. 2
(under the condition that the door control system
monitors the sensor at least once per door cycle)
IEC 61496-1:2012 ESPE Type 2
EN 16005:2012 Chapter 4.6.8
DIN 18650-1:2010 Chapter 5.7.4
BS 7036-1:1996 Chapter 8.1
All values measured in specific conditions.