INFRARED SAFETY FIELD
OR
Activate the visible* spots to verify the
position of the AAIR-curtain.
** The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 8 in.
Part of the detection field can be masked to reduce it.
The arrow position determines the width of the detection field.
Mounting
Detection
width
height
6.5 ft
6.5 ft
7.2 ft
7.2 ft
8.2 ft
8.2 ft
9.8 ft
d max
11.5 ft
d max
4
SETUP
SETUP 1 (QUICK)
reference picture
SETUP 2 (ASSISTED)
test of full door cycle +
reference picture
TEST THE PROPER OPERATION OF THE INSTALLATION BEFORE LEAVING THE PREMISES!
75.5816.06 IXIO-DT1 V UL 20161220
CLOSER
AWAY
If necessary, adjust the AAIR-curtain
angle (from -7° to 4°, default 0°).
* Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
STEP OUT OF THE INFRARED FIELD!
+
Always verify the actual detection field width
with a piece of paper and not the Spotfinder,
which detects the whole emitted field.
The size of the detection field varies according to the moun-
ting height and the settings of the sensor.
The full door width must be covered.
+
+
DOOR
max.
3 in**
Additional
adjustments
are possible by
LCD or remote
control
(see p. 5)
OR
2 s
4 s
Page 3 of 8