Voltage Regulator - BEA IXIO-DT1 V Manuel D'installation

Masquer les pouces Voir aussi pour IXIO-DT1 V:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IXIO-DT1: INSTALLATION GUIDE
1
MOUNTING & WIRING
Mounting is compatible with the WIZARD.
Sensor and camera power must be supplied from a Class 2 supply source limited to 15 W.
Sensor is intended to be monitored for proper operation by the door operator or system.
Harness shall be routed separated from any Mains or non-Class 2 voltage cable for correct operation or shall be rated for the Mains voltage,
and suitable protection and routing means shall be used according to National and Local Codes to prevent damage to the harness.
CAMERA
2
RADAR OPENING IMPULSE FIELD
from 15° to 45°, default 30 °
13 ft x 6.5 (wide)
Page 2 of 8
Sensor connectivity (power and relays) must utilize only the supplied harness.
field size: 9
immunity: 2
7.2 ft
field size: 9
immunity: 2
7.2 ft
12-24 V AC, 50/60 Hz
12-30 V DC
Max 2.5 W
*
*
* Output status when sensor is operational
Voltage
Regulator
from -15° to 15°, default 0°
6.5 x 8 ft (narrow)
The size of the detection field varies according to the mounting height of the sensor.
75.5816.06 IXIO-DT1 V UL 20161220
RED
POWER SUPPLY
BLACK
WHITE
OPENING INPUT
GREEN
YELLOW
BROWN
BLUE
SAFETY INPUT
PURPLE
TEST
PURPLE
OUTPUT
field size: 9
immunity: 2
7.2 ft
field size: 9
immunity: 2
7.2 ft

Publicité

Table des Matières
loading

Table des Matières