Rothenberger Industrial RO-LASERMETER 35 Notice D'utilisation page 26

Télémètre laser
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
1500000597,98_Anleitung_fbg_D,GB,F,I,H,SLO.qxd:PRINT
Memory
Press the memory button (7) to recall up to the last twenty results (distances and
calculated values) in reverse order. Press the plus button (5) or the minus button (-) to
navigate through the results.
To delete the memory navigate to the memory mode. Keep the memory button (7)
depressed and press the OFF button (10). All results are deleted from the memory and a
"0" appears on the display.
Troubleshooting
Fault
Blank or faded display. Batteries low or empty.
Machine cannot be
switched on.
Device always shows
the same result.
Error code 204
Error code 208
Error code 209
Error code 252
Error code 253
Error code 255
Possible cause
Batteries low or empty.
Hardware error.
Calculation error.
Reflected signal is too weak,
measuring period is too long
(Distance eventually > 35 / 50 m)
Reflected signal is too strong
(reflecting object)
Temperature too high
Temperature too low.
Hardware error.
26
18.02.2015
12:28 Uhr
Corrective action
Replace all batteries.
Check that the batteries are
inserted correctly and
replace all batteries if
necessary.
Restart the device several
times. If the symbol does not
disappear contact a qualified
service centre.
Repeat the sequence of
measurements.
Use a good target surface
(see measuring conditions)
Use a good target surface
(see measuring conditions)
Let the device cool down
Warm up the device.
Restart the device several
times. If the symbol does not
disappear contact a qualified
service centre.