When the message Frequency 474.00MHz is displayed on the PS
programmer, you can enter the central frequency of the channel you wish to
process.
Note: You must enter the data of the central frequency completely, including
decimals. However, do not enter the decimal point, which will be placed in
the correct position automatically as you key in the data.
To change to channel or frequency mode, go to the Table channels
screen. Use the
mode. Press
module.
CAUTION, It is recommended that, before starting to program, you should
make a plan of the channels you want and note this information in the
corresponding boxes of the module. By doing so, you will avoid selecting
channels already taken. Make sure that the output channels are not being
used in the distribution. To test the programming of the module, use the
READ function.
7.

COPY OF DATA

The COPY function can be used to avoid having to transmit all the data of
the ZA module one datum at a time. Once the data have been memorised
by the programmer, point the programmer at the PA amplifier and press the
F and COPY keys. You must keep the PS programmer pointed at the
amplifier until the message Copy... disappears from the screen. All the
data will be transmitted to the ZA module.
During this transmission, the PRG indicator of the amplifier (12) and of the
ZA module (25)(37) will blink steadily.
Note: In copying data, the level adjustment values are not transmitted.
Once the ZA module has been programmed, deactivate programming
mode by pressing the programming pushbutton (28)(40) again.
8.

READING DATA WITH THE PS PROGRAMMER

While pointing at the receiver, press the F and READ keys. The message
Read... will appear on the screen. All of the data programmed in the
module are read.
While reading is in progress, the PRG indicator of the amplifier (12) and of
the ZA module (25)(37) blink steadily.