10. ADJUSTMENT OF LEVELS
10.1 Levels of the ZA modules
To perform an equalisation of all the filters, select Automatic level
adjust in the programmer and press T. The digital channels will be
adjusted 10 dB below the analogue channels.
Note: For multichannel filters, the adjustment will be made for the channel
with most level. It is recommended that there should be only one analogue
channel per multichannel filter. If there are more, it is recommended that the
levels of the analogue channels be similar.
FM/DAB
UHF
PRG
Fig. 11 - Automatic adjustment of the levels of the modules
CAUTION, If a channel in the monochannel configuration or the channel
with most level in the multichannel configuration fails to reach or exceeds the
range of values shown in the technical datasheet, the correct input level
indicator IN (24)(36) of the ZA module will continue to blink.
FM/DAB
UHF
PRG
SERIE 905-ZA
OUT
OUT
Fig. 12 - Level failure at input
IN
PRG
IN
PRG
ENG - 45