4.2. Problems in the temperature sensor module
The receiver receives signals from sensors, but fails to registrate
signals from one sensor in particular.
Potential problems:
-
Batteries are missing or are at a low charging level
-
Reversed polarity of the sensor's batteries
-
The sensor's location is outside of the receiver's reception range
-
Damage to the sensor (by corroded battery contacts, moisture
or battery leakage)
-
Problems in the radio signal communication
Suggested solutions:
-
Insert fully charged batteries in the sensor and repeat the
communication test (please check the polarisation of the
batteries before inserting!!)
-
Check the battery contacts and remove all corrosion and
moisture effects.
Type:
Radio:
USB:
Supply:
RTC battery:
Internal memory:
Software:
Extra information and possible updates can be found on www.arexx.com
Further questions can also be put on our forum, see www.arexx.com
Technical details
BS-510
ISM 433MHz, Multilogger RF-protocol.
USB 2.0, Multilogger USB-protocol.
5– 7,5V DC / 500mA
CR2032 3V
2MB data-flash, about 9 days for
10 sensors, 18 days for 5 sensors, etc.
http://www.arexx.com