READ CAREFULLY THE FOLLOWING WARNINGS BEFORE PROCEEDING
WARNING: ALWAYS DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING TO INSTALL OR CARRY OUT
MAINTENANCE ON THE PUMP.
WARNING: WE RECOMMEND INSTALLING THE PUMP IN A VERTICAL POSITION TO ENSURE PROPER OPERATION.
WARNING: PRODUCT INTENDED FOR PROFESSIONAL USE ONLY, BY QUALIFIED PERSONNEL.
WARNING: THE MAINTENANCE OF THE PUMP MUST BE CARRIED OUT BY QUALIFIED AND AUTHORIZED
PERSONNEL.
H
SO
SULPHURIC ACID
-
2
4
hydraulic parts.
The ambient temperature must not exceed 40°C. The relative humidity must be lower than 90%. The pump protection
-
class is IP65. Do not install the pump in a place where it would be in direct sunlight.
-
Secure the pump firmly into place in order to avoid excessive vibrations.
The power-supply voltage available in the system and the working pressure must be compatible with those indicated on the
-
pump label.
WIRING CONNECTIONS
HYDRAULIC CONNECTIONS
2
4
6
6
4
8
11
4
6
6
4
13
EM00136493
TO INSTALL OR CARRY OUT MAINTENANCE ON THE PUMP.
Before dosing chemicals that could react with water it is necessary to dry all the internal
Input A
Power supply 110 ÷
230Vac (50 Hz)
1
3
5
7
5
9
10
14
5
12
5
3
The pump should be connected to a power supply
complying with the indications shown on the label on
the pump side. Failure to comply with the limits
indicated may cause damage to the pump.
These pumps have been designed to absorb minor
over voltages However, in order to prevent any
damage to the pump it is always preferable to avoid
connecting it to the same source of power as electrical
equipment that generates high voltages.
The connection to the three-phase 380V line MUST
always be made solely between phase and
neutral. No connections should
be made between phase and earth.
1.
Injection point
2.
Injection coupling
3.
Gasket
4.
Washer holder
5.
Pipe clamp
6.
Ring nut
7.
Delivery pipe (rigid)
8.
Delivery coupling
9.
Pumping body
10.
Bleeding valve
11.
Suction coupling
12.
Suction hose (soft)
13.
Foot filter
14.
Bleeding valve coupling
rev. 1.0 EN
2