Paragraph 3 – Proportional dosing for the Redox (O.R.P.) measurement
Programming
EM00136493
The pump measures and controls the Redox value of a solution, by
programming
the
following
proportional band and alarm band.
Set-point type: maximum
s/m
max
flow-rate
Pump Off
0
Alarm Band
Set-point type: minimum
s/m
max
flow-rate
0
Alarm Band
Can also be programmed:
- The O.F.A. (Over Feed Alarm) time in minutes, a set period of time after
which, if the measured Redox value does not reach the set-point, an
alarm signal is activated.
- The resolution of the measurement (1 or 2 digits)
- Activation / deactivation of the calibration procedure
The maximum frequency can be changed during the operation by
pressing
+
Display during operation
rev. 1.0 EN
Operation
parameters:
Proportional
Band
Alarm Band
Proportional
Band
Pump Off
Alarm Band
simultaneously.
set-point,
set-point
type,
mV