Paragraph 7 – Flow Rate Calibration
Programming
Paragraph 8 – Statistics
Programming
EM00136493
On the main menu appears the memorized cc/stroke value.
You can perform the calibration in two modes:
MANUAL – insert manually the cc/stroke value using the
key and then confirm with the
AUTOMATIC – the pump runs 100 strokes, which are
started by pressing the
strokes insert the amount aspirated by the pump using the
key and confirm with the
The data entered will be used for the calculation of the flow
rates.
On the main menu is displayed, in hours, the operating time
of the pump; press
- Strokes = the number of strokes performed by the pump
- Q.ta (L) = the quantity dosed from the pump expressed in
liters; this information is calculated based on the memorized
cc/stroke value
- Power = the number of pump activations
- Reset = press
(NO), then press
Press
to return to the main menu.
rev. 1.0 EN
Operation
key.
key, and at the end of the
key.
Operation
to access other statistics:
to reset the counters, select (YES) or
to confirm.
10