EN
Do not use strong solvents or detergents on the plastic
housing or components.
Remove the battery pack from the machine before
maintenance.
11.1 CLEAN THE MACHINE
The machine must be dry. Humidity can cause risks of
electrical shocks.
•
Clear the unwanted material out of the air vent with
a vacuum cleaner.
•
Do not spray the air vent or put the air vent in
solvents.
•
Clean the housing and the plastic components with
a moist and soft cloth.
12
TRANSPORTATION AND
STORAGE
Remove the battery pack from the machine before
tranportation and storage.
12.1 MOVE THE MACHINE
•
Only hold the machine with the handgrip.
12.2 STORE THE MACHINE
•
Clean the machine before storage.
•
Make sure that the motor is not hot when you store
the machine.
•
Make sure that the machine does not have loose or
damaged parts. If it is necessary, do these steps/
instructions:
•
Replace the damaged parts.
•
Tighten the bolts.
•
Speak to a person of an approved service
center.
•
Store the machine in a dry area.
•
Make sure that children cannot come near the
machine.
CAUTION
WARNING
CAUTION
WARNING
English
13
TROUBLESHOOTING
PROBLEM
The motor does
not start when
you pull the trig-
ger.
The machine
does not start.
The air does not
flow through the
tube when you
start the ma-
chine.
14
TECHNICAL DATA
Voltage
Air volume
Air speed
Weight (without
battery pack)
Battery model
Charger model
The recommended ambient temperature range:
Item
Blower storage tempera-
ture range
Blower operation tempera-
ture range
Battery charging tempera-
ture range
Charger operation temper-
ature range
8
POSSIBLE
SOLUTION
CAUSE
Make sure that
The battery pack
you tighlty install
is not installed
the battery pack
tightly.
in the machine.
The battery pack
Charge the bat-
is out of power.
tery pack.
The power switch
is defective.
Replace the de-
The motor is de-
fective parts by
fective.
an approved
service center.
The PCB board is
defective.
The air inlet or
Remove the
tube outlet has a
blockage.
blockage.
24 V
330 CFM
100 MPH (160.9 Km/h)
3.3 lbs. (1.5 kg)
BAG series or LB24A020 / 29842
battery
CAG series or 29862 charger
Temperature
-4°F (-20°C) - 158°F
(70°C)
-4°F (-20°C) - 104°F
(40°C)
39°F (4°C) - 104°F (40°C)
39°F (4°C) - 113°F (45°C)